Archaea Banner
Home
Editors
Contents
Contribute
Subscribe
Contact
Tree Physiology, 20:1057–1062
© 2000 Heron Publishing—Victoria, Canada
[ PDF ]  [ Return to Contents ]  [ Export citation ]

Temperature variations and distribution of living cells within tree stems: implications for stem respiration modeling and scale-up

Jan Stockfors (1)

1. Department for Production Ecology, SLU, Box 7042, SE-750 07 Uppsala, Sweden (jan.stockfors@spek.slu.se) / Received August 12, 1999

Summary

Few studies have examined variation in respiration rates within trees, and even fewer studies have focused on variation caused by within-stem temperature differences. In this study, stem temperatures at 40 positions in the stem of one 30-year-old Norway spruce (Picea abies (L.) Karst.) were measured during 40 days between July 1994 and June 1995. The temperature data were used to simulate variations in respiration rate within the stem. The simulations assumed that the temperature–respiration relationship was constant (Q10 = 2) for all days and all stem positions. Total respiration for the whole stem was calculated by interpolating the temperature between the thermocouples and integrating the respiration rates in three dimensions. Total respiration rate of the stem was then compared to respiration rate scaled up from horizontal planes at the thermocouple heights (40, 140, 240 and 340 cm) on a surface area and on a sapwood volume basis. Simulations were made for three distributions of living cells in the stems: one with a constant 5% fraction of living cells, disregarding depth into the stem; one with a living cell fraction decreasing linearly with depth into the stem; and one with an exponentially decreasing fraction of living cells. 

Mean temperature variation within the stem was 3.7 °C, and was more than 10 °C for 8% of the time. The maximum measured temperature difference was 21.5 °C. The corresponding mean variation in respiration was 35% and was more than 50% for 24% of the time. Scaling up respiration rates from different heights between 40 and 240 cm to the whole stem produced an error of 2 to 58% for the whole year. For a single sunny day, the error was between 2 and 72%. Thus, within-stem variations in temperature may significantly affect the accuracy of scaling respiration data obtained from small samples to whole trees. A careful choice of chamber position and basis for scaling is necessary to minimize errors from variation in temperature.

Keywords: conifer, metabolism, upscaling, woody tissue.


ISSN 0829-318X Copyright © 2002–2008 Heron Publishing